导航
更多
详细内容

Medical Gas Central Piping System

Supports the stable supply
of medical gases more safely and more securely.

e_gassys.png


The medical gases used in a hospital are life-supporting element that gives direct influence in maintaining the life of a patient. Therefore, at the sections where the medical gases are used, the medical gas must be clean, highly pure and supplied under stable pressure.Our medical gas system has cleared those regulations and standards as well as passing our strict company standard. The system has a thoroughgoing color coordination according to the kind of gas, an audio-visual monitoring system capable of checking the situation, and a device to prevent cross connection at medical gas outlet based on the concept, "more safely" and "more securely"


Medical Gas Supply


To maintain a stable supply of medical gases,it is necessary to establish a monitoring system which surely traces the flow of invisible gas from the source of supply through piping to the section to use the gas.We have been offering various monitoring systems which are possible to grasp the information of supply source such as the amount of gas remaining in the right and left banks of manifold and the operating condition of supply station and the pressure of gas supplied at each area of section where the gas is used. In this system, a supply pressure down and a supply station's malfunction are surely grasped by audio-visual tracing.

d.jpg

                                                                                          MAIN ALARM PANEL                                   AREA ALARM PANEL

TERMINAL UNIT


The medical gas outlet which the medical staff such as doctors and nurses use for daily medical care must be so designed as not to allow a cross connection to a different medical gas not intended.We have developed a pin guide system to prevent a cross connection mechanically and, furthermore, we adopted a visual identification system by use of colors respectively designated to the exclusive kind of gas, obtaining a remarkable effect. In order to prevent a cross connection when attaching a medical gas outlet valve at the time of installation or maintenance, a pin guide system is adopted to the valve base of wall type outlet, and DISS standard is applied to the hose connecting section in the case of reel type and ceiling type outlets.

                                                                                      CPS TYPE OUTLET                                              NSV TYPE OUTLET


SPECIAL TYPE OUTLET


                                                                                       CEILING COLUMN (RETRACTABLE)  MOTOR DRIVEN CEILING COLUMN

                                                                                              CEILING TYPE OUTLET                        REEL TYPE OUTLET

                                                                                                                                 CEILING MODULE

e20050117_4.jpg

                                                                                                                 ANESTHETIC GAS SCAVENGING SYSTEM
                                                                                                                                FLOW CONTROL UNIT

NITROGEN CONTROL UNIT


SECONDARY EQUIPMENT

The secondary equipment which is used by connecting to the medical gas outlet must have high accuracy to control the medical gas flow correctly and sure performance to maintain this function.

    1639115250738347.jpg

HUMIDIFIER                                   WALL SUCTION UNIT

     

KICK SUCTION UNIT                                            UNI INJECTOR


      1639115237814857.jpg

OUTLET STAND                                               ADAPTER

Berlin Shengkang Air Oxygen Technology Co., Ltd.
Address:Address: No. 212, Keji Road, High-tech Development Zone, Weihai City, Shandong Province
Zip code: 264210     Tel: 0631-5690001
site :SUEON     鲁ICP备18018910号

Enterprise official website

seo seo